The effluent from the domestic sewage system meets the standards of “Urban Wastewater Reuse – Urban Miscellaneous Water Quality” (GB18920-2020):

pH: 6.0 9.0
Turbidity: ≤10 N U
BOD: <10 mg/L
Ammonia Nitrogen: <8 ng/L

2.2.2 Performance Guarantee Values ​​Technical Guidelines for Coal-Containing Wastewater Treatment Systems GB/T 42866-2023

The effluent from the coal-containing wastewater treatment system meets the standards of “Coal Chemical Wastewater Treatment and Reuse” (pH: 6.0-9.0, color: 530, turbidity: ≤10WIU). The company’s main products and services cover the entire chain of municipal sewage, industrial wastewater, pure water equipment, and waste gas treatment equipment, achieving efficient implementation from precise design and large-scale production to professional construction. Especially in the fields of high pollution and high-difficulty wastewater treatment such as chemical, pharmaceutical, battery new energy, new materials, various mining, and food processing industries, the company has set an industry benchmark with its customized solutions and excellent treatment results.